Checking components and wiring
Check the leak diagnostic unit connectors. Check for contact resistance and oxidation.
Check the resistance of the pump motor between the leak diagnostic unit connector terminals #1 and #4 (leak diagnostic pump side).
Check the hose between the leak diagnostic unit and the EVAP canister. Check for blockages.
Try a new leak diagnostic unit if no fault is found during the above fault-tracing.
Remedy as necessary.
Other information:
- For resistance values, see Component specifications
- To connect the breakout box, see Connecting the breakout box
- To access or replace the leak diagnostic unit, see Leak diagnostic pump, replacing
- To check the hoses, see Leak diagnostic pump, replacing
- For information about signals on 5 cylinder engines, see Signal specification
- For information about signals on 6 cylinder engines:
- For 6 cylinder engines -2001, see Signal specification
- For 6 cylinder engines 2002-, see Signal specification
- For 6 cylinder engines -2004, see Signal specification
- For 6 cylinder engines 2005-, see Signal specification .
- See Contents .
- Continue
Refer to Verification