LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2017 >> Forester 2.0XT Premium >> Repair and Diagnosis >> Electrical >> Gauges >> Instrumentation System & Driver Information Center >> Multi-function Display (MFD) System >> Inspection >> Check Clock System Communication Circuit

Check Clock System Communication Circuit

  1. CHECK POWER SUPPLY  .
    1. Disconnect the MFD connector.
    2. Turn the ignition switch to ON.
    3. Measure the voltage between MFD connector and chassis ground.

    Connector & terminal 

    (i122) No. 3 (+) - Chassis ground (-):

    Is the voltage 10 V or more?

    • Yes: Go to 2  .
    • No: Repair or replace the harness.
  2. CHECK GROUND CIRCUIT  .

    Measure the resistance between MFD connector and chassis ground.

    Connector & terminal 

    (i122) No. 2 - Chassis ground:

    Is the resistance less than 10 Ω?

    • Yes: Go to 3  .
    • No: Repair or replace the harness.
  3. CHECK MFD  .
    1. Remove the MFD.
    2. Attach the clock to another vehicle on which the clock display operates normally, and check its operation.

    Is MFD normal?

    • Yes: Repair the poor contact of connector.
    • No: Replace the MFD.