Stator to Impeller Interference Check
- Position front pump with splined end of stator shaft pointing up. Mount converter on pump so splines of one-way clutch inner race engage splines of stator support, and converter hub engages pump drive gear.
- While holding pump stationary, rotate converter counterclockwise. Converter should rotate freely without interference. If this condition exists, replace torque converter.