  1. CHECK HARNESS AND CONNECTOR (SEAT BELT CONTROL ECU - BATTERY AND BODY GROUND) 
    1. Disconnect the G34 ECU connector.
      GTY667717Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      G34-7 (+B) - Body ground Always 11 to 14 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      G34-8 (PGND) - Body ground Always Below 1 Ω
      TEXT IN ILLUSTRATION

      *a Front view of wire harness connector
      (to Seat Belt Control ECU)

    Result: 

    OK 

    REPLACE SEAT BELT CONTROL ECU 

    (Refer to REMOVAL [08/2015 - 08/2019] )

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR