Circuit/System Testing
- Ignition OFF, disconnect the STRTR relay.
- Ignition OFF and scan tool disconnected, open and close the driver door, and wait 1 minute. Test for less than 5 Ω between the ground circuit terminal 85 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Connect a test lamp between the control circuit terminal 86 and the ground circuit terminal 85.
- Turn the ignition switch to the start position. The test lamp should turn ON only when the ignition is held in the start position, for no longer than 10 seconds.
- If the test lamp is always ON, test the control circuit for short to voltage. If the circuit tests normal, replace the ECM.
- If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the relay.