Removal Procedure
- Disconnect the instrument panel (I/P) harness electrical connector (2) from the battery current sensor.
- Remove the positive and negative battery cable. Refer to Battery Positive and Negative Cable Replacement (RPO LS4) or Battery Positive and Negative Cable Replacement (RPOs LZE/LZ4/LZ9) .
- Cut the tie straps and electrical tape attaching the battery current sensor to the negative battery cable.
- Squeeze the battery cable branches together.
- Slide the battery current sensor (1) off of the battery cable.
IMPORTANT:
Note the position of the battery current sensor prior to removal.