Component Testing
Relay Test
- Ignition/Vehicle - Off
- Remove the component:KR27C Starter Pinion Solenoid Actuator Relay
- Test for 70 to 110 ohms between the test points:Component terminal 85 & 86
- If not between 70 and 110 ohms
Replace the component:KR27C Starter Pinion Solenoid Actuator Relay
- Go to next step: If between 70 and 110 ohms
- If not between 70 and 110 ohms
- Test for infinite resistance between the test points:
- Component terminal 30/3 & 85/1
- Component terminal 30/3 & 86/2
- Component terminal 30/3 & 87/5
- Component terminal 85/1 & 87/5
- Component terminal 86/2 & 87/5
- If less than infinite resistance
Replace the component:KR27C Starter Pinion Solenoid Actuator Relay
- Go to next step: If infinite resistance
- Connect a 3 A fused jumper wire between the test points:Component terminal 86 & 12 V
Connect a jumper wire between the test points:Component terminal 85 & Ground
- Test for less than 2 ohms between the test points:Component terminal 30 & 87
- If 2 ohms or greater
Replace the component:KR27C Starter Pinion Solenoid Actuator Relay
- Go to next step: If less than 2 ohms
- If 2 ohms or greater
- All OK.