Conditions for Setting the DTC
The PCM detects that the HO2S 2 signal voltage remains below 74 mV during Closed Loop operation for more than 2.5 minutes.
OR
The PCM detects that the HO2S 2 signal voltage remains below 550 mV during power enrichment (PE) mode for more than 16 seconds.